EAST RIVER RACQUET CLUB- 17 INDOOR TENNIS COURTS

FACILITY SPECIFICATIONS

These four “Tennis Domes” were engineered and erected by ASATI CEO Donato Fraioli in 1979. Many indoor clubs were constructed after Mr. Fraioli introduced the first-of-its-kind “Tennis Domes” in 1962. A few of the pioneering tennis clubs which Mr. Fraioli engineered, manufactured and installed prior this famous East River Racquet club are:

Tennis Anyone in Westbury, NY (1963)

Sterling Tennis Club in Corona, NY (1965)

Boulevard Gardens in Queens, NY (1966)

West Side Tennis Club in Forest Hills, NY (1969)

Columbia University in Bronx NY (1969)

Stadium Tennis in Bronx, NY (1969)

Wall Street Racquet Club in NYC (1970)

The Broadmoor Hotel in Colorado (1973)

The Snow Mass Country Club in Colorado (1976)

ASATI domed hundreds of tennis courts worldwide following these revolutionary “Tennis Domes”

These “first of-its-kind “Tennis Dome” structures, were heated and inflated with HVAC units developed by Mr. Fraioli. These first-of-its-kind heater inflation units were indirect fired fully recirculation units that inflated and heated the structure with forced hot air with automatic controls for maintaining a controlled temperature of 65 deg. These structures were equipped with automatic starting back-up blowers that turned on in event of a power failure. The first 1000 watt metal halide lighting fixtures mounted on collapsible poles, and the first unique pressure balanced emergency exit doors Mr. Fraioli patented.

Size: 
(1) 118‘ W x 300‘ L x 40‘ High
(1) 118‘ W x 204‘ L x 40‘ High
(1) 118‘ W x 204‘ L x 40‘ High
(1) 118‘ W x 156‘ L x 40‘ High

Exterior Fabric Envelope:
Translucent Dupont Tedlar 28 ozs. per sq. yard

Interior Thermaliner
Double wall envelope Provided R4 insulation and eliminated noise reverberation

Thermaliner Patents
Fraioli R4

Bias Cable Net System
Engineered and patented by ASATI with a proven 45 year track record, this system provides maximum structural rigidity withstanding 40 lb snow loads and winds over 120 MPH.

Cable-Net Patents
Bias Cable Net Patent

Field Junction Seam Joints
"First of its kind" mechanically sealed joints with aluminum non-rusting clamps.

Emergency Exit Doors
"First of its kind" balanced doors.

Emergency Exit Door Patents
Fraioli Pressure Balanced Exit Doors

Heating and Pressurization
Mr. Fraioli developed the first indirect fully modulation and recirculation heater inflation units for air supported structures with automatic fail safe back-up inflation blowers

Building Codes
Mr. Fraioli, with NYC building code authorities, developed the first codes for air supported structures as written in the NYC code #718 for Air Supported Structures. ASATI  exceeds these early code standards.